Measuring ranges | Smallest measuring range: 0…200 mbar / 2 mH2O |
| Largest measuring range: 0…20 bar / 200 mH2O |
Analog output | 4…20 mA, 2-wires |
| 4…20 mA, 2-Leiter, II 1G Ex ia IIC T4 Ga |
Power supply | 20 mA output: 12…30 V DC |
Accuracy | ≤ ± 0,25 % FS @ 25 °C ≤ ± 0,5 % FS @ 25 °C at pressure range ≤ 250 mbar |
Long term stability | ≤ ± 0,2 % FS / Year |
Response time | 200 ms - others on request |
Switch-on time | < 1 s |
Temperature coefficient | Zero: ≤ ± 0,02 % FS / Kelvin ≤ ± 0,04 % FS / Kelvin at pressure range ≤ 250 mbar |
| Span: ≤ ± 0,02 % FS / Kelvin |
Medium temperature | -20…100 °C |
Storage temperature | -40…85 °C |
Short-circuit resistance | Permanent |
Reverse polarity protection | Protection against reverse polarity, but no function |
Electromagnetic compatibility | Interference emissions and immunity acc. to EN 61326 |
Wetted materials | Housing: CrNi-steel 1.4571 |
| Sensor: CrNi-steel 1.4571 |
Protection type | IP 68 |
Weight | Approx. 700 g with 5 m Cable |