Features
- Microwave level switch for media with >20% water content
- Not influenced by foam or adhesions
- Hygienic installation in accordance with EHEDG
- Wetted parts compatible with FDA requirements
- Vibration resistant
- LED indicator
Features
Description
Using high frequency microwaves, the FM2 level switch detects even non-conductive media. Foam and build-up remain undetected until the level reaches the measuring tip. By avoiding hidden edges and dead spaces, optimal cleaning and maintenance can be ensured. Various electrical connection options and a switching output allow easy integration. Dust and water ingress is reliably prevented by IP 67 protection. Feel free to contact us if you need a customization that is not listed in this datasheet.
Request Level switch
|